pay-off

 

Ask for a quote Visit website
Find dealers / rentals

Write a review

GeoSwath 4 500 kHz


 
General 
Product Name:GeoSwath 4 500 kHz
Description:Kongsberg GeoAcoustics GeoSwath Plus offers very efficient simultaneous swath bathymetry and side scan seabed mapping with accuracies that have been shown to exceed the IHO Standards for Hydrographic Surveys.
Date of first release:2002
Mounting and deployment 
Mounting:Hull mounted & Portable
Retractable:Y
Physical properties of transducer head 
Length [m]:0.26
Width [m]:0.11
Height [m]:0.06
Min. external power [V]:108
Max. external power [V]:218
Max. power consumption [W]:148
Used Sonar Methods 
Type of system:Phase Measuring Bathymetric Sonar
Bottom Detection Method:Vernier Phase Detection
System Parameters 
Min. frequency [kHz]:500
Max. frequency [kHz]:500
Number of selectable frequencies:
Min. depth [m]:0
Max. depth [m]:50
Depth resolution [mm]:1.5
Max. Slant Range [m]:97.5
Max. swath as a function of depth:12
Max. measurements per ping:1300
Ping frequency [Hz]:30
Min. beam width across track [deg]:0.01
Min. beam width along track [deg]:0.5
Bottom Coverage 
Footprint in nadir direction [m]:1.55
Footprint at max. horizontal range [m]:3
Smallest identifiable cube [m3]:1
Max. swath width [m]:167
Equal footprint spacing:Y
Max. number of points per ping for side scan operation:26000
Uncertainty 
RMS of nadir depth measurement [m]:0.03
Intended S44 order:Special
Max. survey speed for specified RMS [kt]:7
Speed of sound 
Real-time correction of refraction at transducer head:Y
Real-time integration of SV-profile:Y
Explanation of SV-profile application process:SVP can be imported as file and applied in real time to data
Motion compensation 
Motion sensors compatible to the system:All standard
Required pitch uncertainty [deg]:0.05
Required roll uncertainty [deg]:0.05
Required heave uncertainty [m]:0.05
Interfaces 
Compatible software:All standard processing packages including QPS Qinsy and Hypack (real time) and Caris HIPS and SIPS; IVS3D Fledermaus
Compatible hardware:Any standard
Real-time access procedure:Data broadcast via Ethernet or file export
Maintenance criteria 
Mean time before failure [hr]:999999999
Mean time to repair [hr]:1
More information 
Distinguishable features:Its field of view of 240
 


Ask for a quote Visit website
Find dealers / rentals


Supplier Information

 

 

Download the Brochure
All Product Categories