The world’s largest product database for
surveying, navigation and machine guidance


Ask for a quote Visit website Find dealers / rentals

Write a review


Product Name:Smart•X
Year of Initial Development:2010
Weight in air [kg]:1.94
Weight in water {kg}:
Diameter [mm]:46
Length [mm]:42
Housing material:
Max. cable length [m]:1200
Min. operating power [V]:
Max. operating power [V]:
Battery type:None
Battery duration [hr]:
Max. depth [m]:6000
Max. pressure [bar]:1000
Operating temperature: min. [°C]:
Operating temperature: max. [°C]:
Pressure, temperature and conductivity sensor 
Pressure sensor:
Type of pressure sensor:
Resolution of pressure [% FS]:0.02
Uncertainty of pressure [% FS]:0.05
Temperature sensor:
Type of temperature sensor:
Min. temperature [°C]:-5
Max. temperature [°C]:65
Resolution of temperature [°C]:0.001
Uncertainty of temperature [°C]:0.005
Conductivity sensor:
Type of conductivity sensor:
Max. conductivity [S/m]:9
Resolution of conductivity [10^-3 S/m]:0.1
Uncertainty of conductivity [10^-3 S/m]:0.01
Min. depth increment [m]:0.1
Min. time increment [s]:0.04
Max. salinity [psu]:42
Resolution of salinity [psu]:0.001
Uncertainty of salinity [psu]:0.01
Min. sound velocity [m/s]:500
Max. sound velocity [m/s]:2000
Resolution of sound velocity [m/s]:0.001
Uncertainty of sound velocity [m/s]:0.025
Additonal sensors 
Standard sensor:Conductivity (C•Xchange) Sound Velocity (SV•Xchange) Pressure (P•Xchange) Temperature (T•Xchange) Turbidity (Tu•Xchange)
No. of additional sensors:
Dissolved oxygen:
Dissolved oxygen sensor type:
pH :
pH sensor type:
ORP sensor type:
Fluorescense sensor type:
Cholophyll sensor type :
PAR sensor type :
Light transmission:
Light transmission sensor type :
Optical backscatter :
Optical backscatter sensor type:
Hydrocarbones :
Hydrocarbones sensor type:
Current sensor:
Current sensor type:
Turbidity :
Turbidity sensor type :
H2S :
H2S sensor type :
Redox :
Redox sensor type:
Other optional sensors:
Data and connectivity 
External recorder required:Y
Direct data reading:
Internal memory:
Internal Memory [MB]:
Type of internal memory:
Max. number of samples for self-recording [10^3]:
Dedicated surface data logger:N
Dedicated sub-surface data logger:N
Telemetry link to remote location:N
Software specifications 
Software name:SeaCast
Graphical presentation:Y
Raw data editing:N
Re-computation with raw data:N
CTD Probe controller:Y
Recording with third party software:Y
Operation characteristics 
Data display on dedicated hardware:N
Display of analogue data:N
Method of first recording:Power Up
More information 
Distinguishable features :X•Series instruments can be configured with different parameters and sensor ranges ultilizing Xchange Swappable Sensors. Compatible with UV•Xchange biofouling control.

Ask for a quote Visit website Find dealers / rentals

Supplier Information