Bathyswath-2-STD 234kHz

Product Name:Bathyswath-2-STD 234kHz
Date of first release:2014
Mounting and deployment 
Mounting:Hull mounted & Portable
Physical properties of transducer head 
Length [m]:0.34
Width [m]:0.055
Height [m]:0.10
Min. external power [V]:9
Max. external power [V]:36
Max. power consumption [W]:20
Used Sonar Methods 
Type of system:Interferometric Bathymetry; Sidescan
Bottom Detection Method:Vernier Phase Detection
System Parameters 
Min. frequency [kHz]:204
Max. frequency [kHz]:264
Number of selectable frequencies:1
Min. depth [m]:0.2
Max. depth [m]:3000
Depth resolution [mm]:6
Max. Slant Range [m]:250
Max. swath as a function of depth:15
Max. measurements per ping:100000
Ping frequency [Hz]:50
Min. beam width across track [deg]:0.1
Min. beam width along track [deg]:0.85
Bottom Coverage 
Footprint in nadir direction [m]:0.74
Footprint at max. horizontal range [m]:
Smallest identifiable cube [m3]:0.5
Max. swath width [m]:500
Equal footprint spacing:Y
Max. number of points per ping for side scan operation:100000
RMS of nadir depth measurement [m]:0.01
Intended S44 order:Special
Max. survey speed for specified RMS [kt]:7
Speed of sound 
Real-time correction of refraction at transducer head:Y
Real-time integration of SV-profile:Y
Explanation of SV-profile application process:Ray-tracing from SV profile
Motion compensation 
Motion sensors compatible to the system:All standard
Required pitch uncertainty [deg]:0.05
Required roll uncertainty [deg]:0.05
Required heave uncertainty [m]:
Compatible software:Compatible with all industry-standard packages, including QINSy, Hypack, SonarWiz, EIVA, CARIS, GeoDas, PDS and Starfix Also, a basic but fully-functioning acquisition and processing package is supplied included in the price of the system.
Compatible hardware:All standard motion sensors and positioning systems Windows computers for software
Real-time access procedure:Ethernet interface to hardware; TCP/IP interface between Bathyswath driver software and external software
Maintenance criteria 
Mean time before failure [hr]:
Mean time to repair [hr]:1